SDS011 Nova Particle Sensor
The Nova SDS011 Particle Sensor makes use of the Laser Scattering Principle in order to detect the concentration of particles in the air. The device detects the scattering of light and the patterns into digital signals. These signals are then processed and amplified.
This particle sensor is based on the Laser Diode. The service life of the Laser Diode is 8000 Hours (maximum). For Live or Real-Time-Data you can set the frequency of the sensor to Once in a second. However, you can prolong the service life by configuring the sensor to one-time in 30 seconds or even one-time in 5 seconds. It depends on the type of data tracking you need to monitor air quality.
Video Presentation of the Product
Structural Layout
Features of SDS011 Particle Sensor
- SDS011 Sensor
- Built-in fan
- Works with the Laser Scattering Principle
- Reliable and consistent digital output
- The expected life of the diode is up to 8,000 hours
- Response time on scene change is less than 10 seconds
- Measurement Parameters: PM2.5 and PM10
- Customizable I/O Output and UART
- Sleep Current: 2mA
- Operating Current (max.): 220mA
- Power Supply Compatibility: 5V
- Operating temperature ranges from -20oC to 50oC
- Range: 0.0-999.9gµ/m3
- Air pressure: 86KPa~110KPa
- Operating Humidity (non-condensing): 9% to 95% RH
- The serial data output frequency is 1Hz
- Corresponding time: 1 second
- Concentration / Particle Resolution Range: 0.3µm to 10µm
- Relative Error: 50%RH / 25oC | +/-15% / +/-10µg/m3
- Counting Yield: 70% @0.3µm / 98% @0.5µm
- Supports UART Communication Protocol
- GPIO Pin Spacing: 2.54mm Pitch
- Parity bit: NO
- Bit Rate: 9600
- Data bit: 8
- Stop bit: 1
- Dimensions: 71mm x 70mm x 23mm / 7.1cm x 7cm x 2.3cm
Form Factor (Unit: mm.)
Nova SDS011 Interface Specs
1. |
CTL |
Reserved / Control Pin |
2. |
1µm |
PWM Output PM2.5 – 0-999µg/m3 |
3. |
5V |
5V Input |
4. |
2.5µm |
PWM Output PM10 – 0-999 µg/m3 |
5. |
GND |
Ground |
6. |
R |
TTL RX of UART |
7. |
T |
TTL TX of UART |
# of Bytes |
Name |
Content |
0 |
Message Header |
AA |
1 |
Commander No. |
C0 |
2 |
Data 1 |
PM 2.5 Low Byte |
3 |
Data 2 |
PM 2.5 High Byte |
4 |
Data 3 |
PM 10 Low Byte |
5 |
Data 4 |
PM 10 High Byte |
6 |
Data 5 |
ID Byte 1 |
7 |
Data 6 |
ID Byte 2 |
8 |
Check-sum |
Check-sum |
9 |
Message tail |
AB |
PWM Output Description
PM2.5 Value Range |
0 µg/m3 to 999 µg/m3 |
PM10 Vale Range |
0 µg/m3 to 999 µg/m3 |
Cycle |
1004ms (+/- 1%) |
High-Level Output Time (to begin with the whole cycle) |
2 milliseconds |
Middle Time (during the middle time of the cycle) |
1000ms (+/- 1%) |
Low-level Output Time (By the end of the whole cycle) |
2 milliseconds |
Items Included
- SDS011 NOVA Particle Sensor (x1)